English | Select | |
한국어 | Select | |
Русский | Select |
GENERAL INFORMATION
INSTRUCTION & FEATURES
Non spill type of Line Blind has good advantages in Oil terminal & offshore applications where is limited installation space and marine pollution is strictly prohibited. The 3 sides covered body & compact design prevents ground pollution and it allows to install at parallel pipe lines.
TECHNICAL SPECIFICATIONS
NOMINAL DIAMETER
NPS 1/2 (DN15) - NPS100 (DN2500)
TEMPERATURE RANGE
Standard Design : -20℃ ~ +200℃
High Temp. Design : +200℃ ~ +816℃
Cryogenic Design : -196℃
PRESSURE RATING
ASME Class 150 to Class 1500
Other presure classes up to ASME 2500
# available upon request
MATERIALS
BODY : Carbon Steel, Stainless Steel, Special Material (Duplex, Hastelloy, Monel, Inconel etc.)
BLIND : Stainless Steel, Special Material (Duplex, Hastelloy, Monel, Inconel etc.)
MOVING PARTS & SEALING SURFACE are Anti-corrosion Materials
FUNCTION
Gas & Liquid Perfect Isolation( Zero Leakage )
OPERATION METHOD
Manual Operation
Electric, Pneumatic or Hydraulic Operation
Part & Description
Operating Instruction
1). Before turning the handwheel to change the blind plate position, internal pressure of the valve must be drained and be sure no pressure(Zero).
2). Unlock locking device for turn to handwheel
3). To change the blind plate position, turn the handwheel clockwise until indicator reaches to “Open” mark.
4). When indicator is on “open” mark, change the blind plate position to open or close.
5). After change the blind plate position, turn the handwheel counter-clockwise until indicator reaches to “Close” mark to tighten the seat.
6). Lock locking device for can’t use ahourized person
APPLICATIONS
OIL TERMINAL - Oil & Chemical tankfarm | OFFSHORE - FPSO |